Huawei SUN2000-17KTL-M2 - General Specifications
Operating temperature range: -25 ~ +60 °C
Operating relative humidity: 0% RH~100% RH
Operating altitude: 0 – 4,000 m (derating > 2,000 m)
Cooling: Convection cooling
Display: Status LEDs
Communication: RS485, WLAN/Ethernet*, 4G /3G/2G*
Weight (including mounting bracket): 25 Kg
Dimensions (including mounting bracket): 525 x 470 x 262 mm
Protection class: IP65
Power consumption at night: < 5.5 W (<10 W when PID recovery function is enabled)
Huawei SUN2000-17KTL-M2 - Input DC
Recommended maximum PV power125,500 Wp
Max. Input voltage2: 1.080 V
Operating voltage range3 : 160 V ~ 950 V
Starting voltage : 200 V
Rated input voltage: 600 V
Max. Input current per MPPT: 22 A
Max. Short circuit current: 30 A
Number of MPP trackers: 2
Max. Number of inputs per MPPT: 2
Huawei SUN2000-17KTL-M2 - Output AC
Mains connection: Three-phase
Rated power: 17,000 W
Maximum apparent power: 18,700 VA
Rated output voltage: 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W + N+PE
AC mains frequency: 50 Hz / 60 Hz
Maximum output current: 28.5 A
Adjustable power factor: 0.8 cap. ... 0.8 ind.
Distortion factor (THD): ≤ 3%
Huawei SUN2000-17KTL-M2 - Efficiency
Max. Efficiency: 98.65 %
European efficiency: 98.30 %
Huawei SUN2000-17KTL-M2 - Protection devices
DC load break switch: Yes
Islanding detection: Yes
AC overcurrent protection: Yes
AC short circuit protection: Yes
DC reverse polarity protection: Yes
AC overvoltage protection: Type II
DC overvoltage protection: Yes, compatible with protection type TYPE II according to EN / IEC 61643-11
Residual current monitoring: Yes
Arc detection: Yes
Ripple control receiver inputs: Yes
Integrated PID recovery4: Yes
Huawei SUN2000-17KTL-M2 - Module Optimizer
SUN2000-450W-P
Huawei SUN2000-17KTL-M2 - Standards and Security
EN/IEC 62109-1, EN/IEC 62109-2
Huawei SUN2000-17KTL-M2 - Power supply conditions
G98, G99, EN 50438, EN 50549, IEC 0-21, IEC 0-16, VDE-AR-N-4105, VDE-AR-N-4110, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, PO 12.3, TOR D4, IEC61727, IEC62116, DEWA
Further information on conformity to standards is available on request.
Huawei SUN2000-17KTL-M2 - included in delivery
PV Connectors
AC connectors
Signal cable connector
Bracket
Huawei SUN2000-17KTL-M2 - Notes and explanations
1 The maximum PV input power of the inverter is 40,000 Wp when long strings are designed and fully connected with SUN2000-450W-P current optimizers.
2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would likely damage the inverter.
3 Any DC input voltage above the operating voltage range may cause faulty operation.
4 SUN2000-12-20-KTL-M2 raises the potential between PV and ground to above zero by built-in PID recovery function to recover the degradation of module from PID. Supported module types are: P-type (mono, poly)